Uploaded image for project: 'SAFe Program'
  1. SAFe Program
  2. SP-3595

Make available a set of notebooks and data-access libraries for reading the QA metrics of the recorded PST complex-voltage observations

Change Owns to Parent OfsSet start and due date...
    XporterXMLWordPrintable

Details

    • Enabler
    • Must have
    • PI20
    • COM PST SW
    • None
    • Data Processing
    • Hide

      Enables easy accessibility to observation parameters and QA metrics by AIV engineers

      Show
      Enables easy accessibility to observation parameters and QA metrics by AIV engineers
    • Hide
      • A published python library can be used to load the QA statistics files written by the PST voltage recorder.
      • Published documentation and notebooks demonstrate how to use the library to perform common QA statistics visualization tasks
      Show
      A published python library can be used to load the QA statistics files written by the PST voltage recorder. Published documentation and notebooks demonstrate how to use the library to perform common QA statistics visualization tasks
    • 1.5
    • 1.5
    • 0
    • Team_PST
    • Sprint 5
    • Hide
      • A new Data Access Library and its published documentation facilitate the extraction and display of data from statistical summary files
      • The PST single scan notebook demonstrates how to use the Data Access Library to
        • display tables of statistical information;
        • plot statistical data; and
        • verify that statistical data are consistent with the known statistical properties of the signal generated by the CBF simulator
      • A new PST data product notebook demonstrates how to download, display and plot the latest statistical summary file from the data product dashboard
      Show
      A new Data Access Library and its published documentation facilitate the extraction and display of data from statistical summary files The PST single scan notebook demonstrates how to use the Data Access Library to display tables of statistical information; plot statistical data; and verify that statistical data are consistent with the known statistical properties of the signal generated by the CBF simulator A new PST data product notebook demonstrates how to download, display and plot the latest statistical summary file from the data product dashboard
    • 20.6
    • Stories Completed, Outcomes Reviewed, Satisfies Acceptance Criteria, Accepted by FO
    • PI22 - UNCOVERED

    • Low-G2

    Description

      During the AIV system integration tests (and later during AA0.5 commissioning), AIV engineers will inject test signal through the signal chain, and PST will record files that should contain the exact signal injected, as well as (much smaller) files containing the QA metrics generated by the PST statistics monitor (in HDF5 format). This work will enable AIV engineers to quickly read the QA metrics stored in the HDF5 files – and display relevant statistics and signal parameters – which will help quick test validation and fault detection.

      The planned structure of the data products delivered by the PST AA0.5 Complex Voltage Recorder is described here: https://confluence.skatelescope.org/display/SWSI/Voltage+Recorder+Data+Products

       

      Attachments

        Issue Links

          Structure

            Activity

              People

                A.Noutsos Noutsos, Aristeidis
                a.jameson Andrew Jameson
                Votes:
                0 Vote for this issue
                Watchers:
                0 Start watching this issue

                Feature Progress

                  Story Point Burn-up: (100.00%)

                  Feature Estimate: 1.5

                  IssuesStory Points
                  To Do00.0
                  In Progress   00.0
                  Complete1011.5
                  Total1011.5

                  Dates

                    Created:
                    Updated:
                    Resolved:

                    Structure Helper Panel